API RP- 2X Practice Test Kit
Description
Designed in the spirit of API RP-2X, these specimens offer a technician advanced training in UT flaw detection & sizing in unique configurations. This kit is a great tool for conducting practical examinations, as well as preparing technicians for typical industry exams.
Material:
- A36 carbon steel plate
 - A106B carbon steel pipe
 - Total of 4 specimens
 - 90° “T” Connection, 0.75” T x 16” (weld length) x 4” (carrier) x ~8” (leg)
 - 60° Diagonal “Y” Connection, 0.75” T x 12” (weld length) x 4” (carrier) x ~8” (leg)
 - Simulated Pipe Splice 1” T x 18” (weld length) x ~12” (~6” either side of weld center line) with 0.25” x 1” Backing Bar
 - Pipe Longitudinal Weld 8” Sch60 (0.406”) x 18” x ~180° segment (~6” either side of longitudinal weld center line)
 
Flaws:
- Total of 11 flaws
 - Flaws are randomly placed ~2-4 flaw per specimen
 - Flaw design and manufacturing intent is to make all flaws rejectable as per API RP-2X Level C acceptance criteria (Fig. 45 & 48).
 - Flaw acceptability must be determined by the end user and will not be determined by ultrasonics during or post manufacturing.
 
Weight:
- ~170LBS
 
Documentation:
- Includes Certificate of Conformance, “As Built” CAD drawings, “Blank” CAD Test Sheets, UT Inspection Report (per FlawTech spec #FT-10-1 Level A) and Measuring & Test Equipment Certificates
 

                    





						
                    